Main Page
Welcome
About the Center
About The SPC
Mission and Vision
Organizational Structure
Spc Directors
Facts and Figures
Services
ِActivities
Exhibitions
Print Exhibition
Books Exhibition
Visits
Training
Workshops
Courses
Seminars
Conventions
Celebrations
Research
Favorite Links
Contact Us
PhotoAlbum
Contact Us
Researches
عربي
English
About
Admission
Academic
Research and Innovations
University Life
E-Services
Search
Scientific Publishing Center
Document Details
Document Type
:
Article In Journal
Document Title
:
An ANN Based Fault Diagnosis System for Tapped HV/EHV Power Transmission Lines
تصميم نظام تشخيص الأعطال لخطوط نقل القوى الكهربائية ذوات التفريعة باستخدام الشبكات العصبية الاصطناعية
Subject
:
Electrical and Computer Engineering
Document Language
:
English
Abstract
:
This paper presents a design for a fault diagnosis system (FDS) for tapped high/extra-high voltage (HV/EHV) power transmission lines (TL's). These tapped lines have two different protection zones. The proposed approach reduces the cost and the complexity of the FDS for these types of lines. The FDS, basically, utilizes fifteen artificial neural networks (ANN's) to reach its output diagnosis. The FDS basic objectives are mainly: 1. the detection of the system fault; 2. the localization of the faulted zone; 3. the classification of the fault type; and finally 4. the identification of the faulted phase. This FDS is structured in a three hierarchical stages. In the first stage, a preprocessing unit to the input data is performed. An ANN, in the second stage, is designed in order to detect and zone localize the line faults. In the third stage, two zone diagnosis systems (ZDS) are designed. Each ZDS is dedicated to one zone and consists of seven parallel-cascaded ANN's. Four-parallel ANN's are designed in order to achieve the fault type classification. While, the other three cascaded ANN’s are designed mainly for the selection of the faulted phase. A smoothing unit is also configured to smooth out the output response of the proposed FDS. The proposed FDS is designed and evaluated using the local measurements of the three-phase voltage and current samples acquired at only one side. A sampling rate of 16 samples per cycle of the power frequency was taken. A data window of 4 samples was also utilized. These samples were generated using the EMTP simulation program, applied to the High-Dam/Cairo 500 kV tapped TL. All possible shunt fault types were considered. The effect of fault location and fault incipience time were also included. Moreover, the effect of load and capacitor switchings on the FDS performance was investigated. Testing results have proved the capability as well as the effectiveness of the proposed FDS.
ISSN
:
1319-1047
Journal Name
:
Engineering Sciences Journal
Volume
:
20
Issue Number
:
1
Publishing Year
:
1430 AH
2009 AD
Number Of Pages
:
25
Article Type
:
Article
Added Date
:
Sunday, October 11, 2009
Researchers
Researcher Name (Arabic)
Researcher Name (English)
Researcher Type
Dr Grade
Email
السيد عبدالعليم محمد
E. A. Mohamed
Researcher
حسام-الدين عبدالله طلعت
H. A. Talaat
Researcher
إيمان علي خميس
E. A. Khamis
Researcher
Files
File Name
Type
Description
23045.pdf
pdf
Back To Researches Page